ERROR CONDITIONS
The GS750
plus
is programmed to detect several
mechanical/electrical error conditions at power-up or during
operation. When an error condition occurs, the plotter will turn off
power to the stepper motors, flash the RUN lights, and sound a
steady tone.
To determine the error condition that stopped plotter operation,
follow these steps.
1. Press the RESET key to clear the error signal (flashing lights
and steady tone).
2. Press the RUN SINGLE key to display the error code number.
The RUN lights flash the same number of times as the error
number (once for Error 1, twice for Error 2, etc.). A short beep
indicates the end of the error message. Press the RUN
SINGLE key again to repeat the message, if desired.
3. Press the RESET key to clear the error display mode and
return to the initial off-line status.