Page view 61
54 GS750
plus
Fuse Replacement
Two spare fuses are included with the GS750
plus
Plotter. The
fuse holder is located between the on/off switch and the power
cord connector on the rear panel of the plotter.
To replace the fuse
WARNING: Turn off power at the plotter and the system and
disconnect from the power supply.
1. Unscrew and remove the RS-232 cable from the rear panel of
the GS750
plus
.
2. Remove the plotter power cord from the socket.
3. Insert a flat-tip screwdriver into the round, notched cover.
Remove the fuse carrier and fuse.
4. Examine the fuse and remove it if it is blown. Install a new
fuse of the same type and rating in the same place. If the
fuse blows again, contact the Gerber Field Service
Department.
5. Reinsert the carrier, making sure the carrier is inserted all the
way. Tighten the screw.
6. Reinstall the power cord and the cable connector. Turn the
power on at the system and at the plotter.