Page view 71
64 GS750
plus
10. When the blade is correctly adjusted, power up the plotter
while holding the RESET key. Load paper and install pen
holder.
11. Press the left arrow key to access the Wagon Wheel Test
Plot. Press either Run key to plot. Compare your test plot to
the Wagon Wheel Test Plot.
12. Turn off power to the plotter. Power-up the plotter while
holding the RESET key. Load vinyl and install knife holder.
13. Press SLOW key to access the Square/Circle Test Plot.
Press either Run key to plot. Compare your test plot to the
Square/Circle Test Plot.
If symptoms persist, call Gerber Field Service Department at 800-
828-5406 or fax at 203-645-2448.